        Vacuum Paddle Dryer

        Pharmadry? - series PH 50 - PH 4000

        The Pharmadry® vacuum paddle dryer with short drying times is well suited for the drying of freely flowing, sensitive pharmaceutical ingredients and fine chemicals. Designed to meet stringent cGMP and FDA guidelines

        Agitator supported at the rear, with externally exchangeable mechanical seal. Designed for frequent product changes. Excellent cleanability using CIP Systems, simple validation. 

        Good product discharge characteristics with negligible product residues, due to narrow agitator to wall clearances, minimal vessel depth and a special agitator blade design.

        product image 1product image 2product image 3product image 4

        Inerting

        Prior to feeding wet cake or slurry into the dryer the vessel interior is inerted by a controlled displacement of the oxygen containing atmosphere with Nitrogen. This procedure prevents the potential formation of an explosive atmosphere in the vessel interior.

        Technical data

        Special properties for the customer’s benefit:

        • calculation, design and manufacture in compliance with Pressure Equipment Directive 97/23/EG or/and ASME U-Stamp as well as with cGMP and FDA guidelines
        • EG type examination certification 03ATEX0246X in accord with PED 94/9/EG or with UL-approved electrical components for operations in class 1, division 1 or 2, group C & D environment
        • double mechanical seal, externally interchangeable, non contacting gas-lubricated (lift-off), dry running contact (contacting sliding surfaces) or liquid-lubricated seal
        • sampler valve
        • pre-piping made of stainless steal on terminal box
        • excellent cleanability using CIP-systems, simple validation


        Options:

        • pressure-resistant and sterile versions, isolators (glove box), DQ, IQ, OQ qualification
        • autonomic PLC control or connected to PMSX, heavy current box

        Technical data

        Dryer
        type
         
        Internal
        Ø
        mm
        Heating area, wetted

         
        Nominal volume
        l
         
        Speed
        max.
        1/min
        Drive
        kw
        PH 50 450 1.1 50 45 3.0
        PH 100 550 1.6 100 35 4.0
        PH 200 650 2.1 150 30 5.5
        PH 300 800 3.1 260 20 7.5
        PH 500 900 4.0 380 14 11.0
        PH 750 1060 5.1 580 12 15.0
        PH 1000 1200 6.4 850 10 18.5
        PH 1500 1350 8.4 1200 9 22
        PH 2000 1480 10.0 1590 8 22
        PH 2500 1580 11.6 1990 8 30
        PH 3000 1700 13.1 2380 7 30
        PH 4000 1870 16.1 3190 6 37